Back to Overview

Alarms – Opto-Acoustical

Back to Overview

BS 601 / 602

Product Description and Application

The alarms BS 60** are used for generating optical and/or acoustical signals in potentially explosive atmospheres. As flameproof or even intrinsically safe versions they can fulfil various tasks - e. g. in underground mines.

 

Combined Alarms "flameproof"

 

  • Available as optical, acoustical, opto-acoustical, flameproof and intrinsically safe version
  • Four different mains AC voltages, from 110 to 1000 V, distinction by different letters within type designation
  • Available with intrinsically safe control
  • Optical part has a light frequency of 1 Hz with xenon photo-flash lamp
  • In case of optical alarms: uv-resistant and impact proof - no protective cage required
  • Even light distribution
  • Electronical two-tone siren, adjustable up to 107 dB
  • Loudspeaker in degree of enclosure protection IP 67
  • Difference between types BS 601 and BS 602 is the nominal energy of their photo flashes of 5 Ws (BS 601) and 10 Ws (BS 602)
  • Activation of all combined alarms by applying a control voltage of 5 V to 15 V (exception: type BS 601 E)
  • Current consumption max. 10 mA
  • On request, control is performed via telephone ringing signal
  • Special feature type BS 601 E: activation of the alarm by applying a supply voltage of 12 V

 

Combined Alarms "intrinsically safe"

 

In addition to the flameproof versions, also the intrinsically safe types BS 601 *I and BS 601 *IS are available. They operate the same way as the types mentioned above.

 

The alarm BS 601 *I is put into operation by applying a supply voltage.  In type BS 601 *IS the supply voltage can remain connected permanently and the alarm is activated by means of an external potential-free contact (e. g. switch, relay or optocoupler).

 

When applying external control a switch-off lag of 0 - 7 seconds can be adjusted in order to bridge breaks in between telephone ringing signals.

 

Type of explosion protection: mining BS 60* *(*): ex I M1 Ex ia I
  ex I M2 Ex de [ib] I
  ex I M2 Ex deq [ib] I
Type of explosion protection: industry BS 60* *(*): ex II 2G Ex de [ib] IIB T5
  ex II 2G Ex deq [ib] IIB T5
BS 606 A: ex II 2G Ex d IIB T6
Degree of enclosure protection ≥ IP 54 (BS 606 A: IP 68)
EC type examination certificate
IBExU 03 ATEX 1147 X

 

Model and Performance Variants

 

BS 601* Opto-Acoustical Alarms „flameproof“
- The alarm is activated by applying an additional control voltage of 5 - 15 Volt
- Nominal energy flash: 5 Ws
BS 602*
Opto-Acoustical Alarms „flameproof“
- The alarm is activated by applying an additional control voltage of 5 - 15 Volt
- Nominal energy flash: 10 Ws
BS 601 E
Opto-Acoustical Alarms „flameproof“
- The alarm is activated by applying a supply voltage of 12 Volt
BS 601*I Opto-Acoustical Alarms „intrinsically safe“
- The alarm is activated by applying a supply voltage of 12 Volt
BS 601*IS Opto-Acoustical Alarms „intrinsically safe“
- Supply voltage can remain connected permanently; the alarm can be activated by an external potential-free contact (e. g. switch, relay-contact, optocoupler)

 

Further models on request!

Design – Technical Specifications

Electrical parameters opto-acoustical alarms "flameproof"

Type
Input voltage
Type of current
Frequency
Rated current
(approx.)
Rated output
BS 601 A
230 V
AC
50/60 Hz
0.12A
26 VA
BS 601 B
500 V
AC
50 Hz
0.055 A
28 VA
BS 601 C
1000 V
AC
50 Hz
0.028 A
28 VA
BS 601 D
110 V
AC
50/60 Hz
0.26 A
28 VA
BS 601 E
12 V
DC
0 Hz
1.0A
12 W
           
BS 602 A
230 V
AC
50/60 Hz
0.15 A
33 VA
BS 602 B
500 V
AC
50 Hz
0.07 A
35 VA
BS 602 C
1000 V
AC
50 Hz
0.035 A
35 VA
BS 602 D
110 V
AC
50/60 Hz
0.32 A
35 VA

 

Electrical parameters opto-acoustical alarms "intrinsically safe"

  BS 601 EI / EIS
Input voltage 12 V
Rated current 0.8 A
Rated output 9.6 W
Rated energy flash lamp 5 Ws
Flash frequency 1 Hz
Loudness level of siren approx. 97 dB

 

Subject to technical modifications!